Parent Layer:
Electric
Name: UG_Transformer
Display Field: SUBNETWORKCONTROLLERNAME
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: a9012455566b41559661b54965bcc320
Copyright Text:
Default Visibility: true
MaxRecordCount: 2000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 1800.0
Max Scale: 0.0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 7807.335400000215
YMin: 5787623.944
XMax: 18486.966599999927
YMax: 5798523.9374
Spatial Reference: 102187
(3776)
LatestVCSWkid(0)
Drawing Info:
Renderer:
Simple Renderer:
Symbol:
Label: N/A
Description: N/A
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: true
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: ASSETGROUP
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
ASSETGROUP
(
type: esriFieldTypeInteger, alias: ASSETGROUP
)
-
ASSETTYPE
(
type: esriFieldTypeSmallInteger, alias: ASSETTYPE
)
-
ASSOCIATIONSTATUS
(
type: esriFieldTypeSmallInteger, alias: ASSOCIATIONSTATUS
)
-
ISSUBNETWORKCONTROLLER
(
type: esriFieldTypeSmallInteger, alias: ISSUBNETWORKCONTROLLER
)
-
ISCONNECTED
(
type: esriFieldTypeSmallInteger, alias: ISCONNECTED
)
-
SUBNETWORKCONTROLLERNAME
(
type: esriFieldTypeString, alias: SUBNETWORKCONTROLLERNAME, length: 2000
)
-
TIERNAME
(
type: esriFieldTypeInteger, alias: TIERNAME
)
-
TIERRANK
(
type: esriFieldTypeInteger, alias: TIERRANK
)
-
TERMINALCONFIGURATION
(
type: esriFieldTypeString, alias: TERMINALCONFIGURATION, length: 128
)
-
GLOBALID
(
type: esriFieldTypeGlobalID, alias: GLOBALID, length: 38
)
-
lifecyclestatus
(
type: esriFieldTypeSmallInteger, alias: Lifecycle Status
)
-
ownedby
(
type: esriFieldTypeSmallInteger, alias: Owned By
)
-
maintby
(
type: esriFieldTypeSmallInteger, alias: Maintained By
)
-
installdate
(
type: esriFieldTypeDate, alias: Install Date, length: 8
)
-
workorderinstall
(
type: esriFieldTypeString, alias: Work Order Install, length: 50
)
-
capitalizeyear
(
type: esriFieldTypeSmallInteger, alias: Capitalize Year
)
-
inservicedate
(
type: esriFieldTypeDate, alias: inservicedate, length: 8
)
-
retireddate
(
type: esriFieldTypeDate, alias: Retired Date, length: 8
)
-
workorderdisposal
(
type: esriFieldTypeString, alias: Work Order Disposal, length: 50
)
-
acquisition
(
type: esriFieldTypeSmallInteger, alias: Acquisition
)
-
usefullife
(
type: esriFieldTypeInteger, alias: usefullife
)
-
assetid
(
type: esriFieldTypeString, alias: Asset ID, length: 64
)
-
SUBNETWORKNAME
(
type: esriFieldTypeString, alias: Feeder Number, length: 2000
)
-
SUPPORTEDSUBNETWORKNAME
(
type: esriFieldTypeString, alias: SUPPORTEDSUBNETWORKNAME, length: 2000
)
-
SUPPORTINGSUBNETWORKNAME
(
type: esriFieldTypeString, alias: SUPPORTINGSUBNETWORKNAME, length: 2000
)
-
plandevicestatus
(
type: esriFieldTypeSmallInteger, alias: plandevicestatus
)
-
normaldevicestatus
(
type: esriFieldTypeSmallInteger, alias: Normal Device Status
)
-
currentdevicestatus
(
type: esriFieldTypeSmallInteger, alias: currentdevicestatus
)
-
winterdevicestatus
(
type: esriFieldTypeSmallInteger, alias: winterdevicestatus
)
-
summerdevicestatus
(
type: esriFieldTypeSmallInteger, alias: summerdevicestatus
)
-
phasesnormal
(
type: esriFieldTypeSmallInteger, alias: Phases Normal
)
-
phasescurrent
(
type: esriFieldTypeSmallInteger, alias: phasescurrent
)
-
phasessummer
(
type: esriFieldTypeSmallInteger, alias: phasessummer
)
-
phaseswinter
(
type: esriFieldTypeSmallInteger, alias: phaseswinter
)
-
phasesplan
(
type: esriFieldTypeSmallInteger, alias: phasesplan
)
-
phasesenergized
(
type: esriFieldTypeSmallInteger, alias: phasesenergized
)
-
nominalvoltage
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-L)
)
-
nominalvoltagelg
(
type: esriFieldTypeInteger, alias: Nominal Voltage (L-G)
)
-
phasefrequency
(
type: esriFieldTypeSmallInteger, alias: phasefrequency
)
-
numphasesconstructed
(
type: esriFieldTypeSmallInteger, alias: Num Phases Built
)
-
designtype
(
type: esriFieldTypeSmallInteger, alias: Design Type
)
-
grounding
(
type: esriFieldTypeSmallInteger, alias: Grounding
)
-
maxvoltage
(
type: esriFieldTypeInteger, alias: Maximum Voltage
)
-
maxoperatingvoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
)
-
compatibleunit
(
type: esriFieldTypeString, alias: compatibleunit, length: 255
)
-
manufacturer
(
type: esriFieldTypeSmallInteger, alias: Manufacturer
)
-
manufacturedate
(
type: esriFieldTypeDate, alias: Manufacture Date, length: 8
)
-
model
(
type: esriFieldTypeString, alias: Model, length: 255
)
-
loadtapchangermaximumchange
(
type: esriFieldTypeDouble, alias: loadtapchangermaximumchange
)
-
loadtapchangerlowerbandwidth
(
type: esriFieldTypeDouble, alias: loadtapchangerlowerbandwidth
)
-
maximumboost
(
type: esriFieldTypeDouble, alias: maximumboost
)
-
z0psimpedance
(
type: esriFieldTypeDouble, alias: z0psimpedance
)
-
z0xmimpedance
(
type: esriFieldTypeDouble, alias: z0xmimpedance
)
-
z1psimpedance
(
type: esriFieldTypeDouble, alias: z1psimpedance
)
-
x0r0impedance
(
type: esriFieldTypeDouble, alias: x0r0impedance
)
-
x1r1impedance
(
type: esriFieldTypeDouble, alias: x1r1impedance
)
-
z0pmimpedance
(
type: esriFieldTypeDouble, alias: z0pmimpedance
)
-
primarygroundimpedance
(
type: esriFieldTypeDouble, alias: primarygroundimpedance
)
-
gridsidecouplinginductance
(
type: esriFieldTypeDouble, alias: gridsidecouplinginductance
)
-
remotecontrollerindicator
(
type: esriFieldTypeSmallInteger, alias: remotecontrollerindicator
)
-
equipmentyype
(
type: esriFieldTypeSmallInteger, alias: equipmentyype
)
-
tripmode
(
type: esriFieldTypeSmallInteger, alias: tripmode
)
-
tapsandpoles
(
type: esriFieldTypeSmallInteger, alias: tapsandpoles
)
-
directional
(
type: esriFieldTypeSmallInteger, alias: directional
)
-
peakload
(
type: esriFieldTypeInteger, alias: peakload
)
-
offpeakload
(
type: esriFieldTypeInteger, alias: offpeakload
)
-
district
(
type: esriFieldTypeString, alias: district, length: 255
)
-
isvalidloop
(
type: esriFieldTypeSmallInteger, alias: isvalidloop
)
-
devicestate
(
type: esriFieldTypeSmallInteger, alias: devicestate
)
-
upperrangemetric
(
type: esriFieldTypeDouble, alias: upperrangemetric
)
-
lowerrangemetric
(
type: esriFieldTypeDouble, alias: lowerrangemetric
)
-
primarygroundimpedance2
(
type: esriFieldTypeDouble, alias: primarygroundimpedance2
)
-
reversetrip
(
type: esriFieldTypeSmallInteger, alias: reversetrip
)
-
p2sphaseshift
(
type: esriFieldTypeSmallInteger, alias: p2sphaseshift
, Range: [-30, 30]
)
-
p2tphaseshift
(
type: esriFieldTypeSmallInteger, alias: p2tphaseshift
, Range: [-30, 30]
)
-
timedelay
(
type: esriFieldTypeSmallInteger, alias: timedelay
, Range: [0, 10]
)
-
tripcount
(
type: esriFieldTypeSmallInteger, alias: tripcount
, Range: [0, 5]
)
-
tapmaxchange
(
type: esriFieldTypeSmallInteger, alias: tapmaxchange
, Range: [-15, 15]
)
-
secondaryvoltagelinetoline
(
type: esriFieldTypeInteger, alias: Secondary Voltage (L-L)
)
-
secondaryvoltagelinetoground
(
type: esriFieldTypeInteger, alias: Secondary Voltage (L-G)
)
-
tertiaryvoltagelinetoline
(
type: esriFieldTypeInteger, alias: tertiaryvoltagelinetoline
)
-
tertiaryvoltagelinetoground
(
type: esriFieldTypeInteger, alias: tertiaryvoltagelinetoground
)
-
optype
(
type: esriFieldTypeSmallInteger, alias: Opt Type
)
-
maximumpower
(
type: esriFieldTypeInteger, alias: Maximum Power
)
-
minimumpower
(
type: esriFieldTypeInteger, alias: Minimum Power
)
-
ratedpower
(
type: esriFieldTypeInteger, alias: Rated Power
)
-
loadtapchangepercent
(
type: esriFieldTypeSmallInteger, alias: loadtapchangepercent
, Range: [-15, 15]
)
-
noloadloss
(
type: esriFieldTypeInteger, alias: noloadloss
)
-
secondarygroundimpedance
(
type: esriFieldTypeDouble, alias: secondarygroundimpedance
)
-
ctratio
(
type: esriFieldTypeInteger, alias: CT Ratio
)
-
ptratio
(
type: esriFieldTypeInteger, alias: PT Ratio
)
-
maximumbuck
(
type: esriFieldTypeDouble, alias: maximumbuck
)
-
secondarygroundimpedance2
(
type: esriFieldTypeDouble, alias: secondarygroundimpedance2
)
-
buckbandwidth
(
type: esriFieldTypeSmallInteger, alias: buckbandwidth
)
-
loadtapchangerupperbandwidth
(
type: esriFieldTypeDouble, alias: loadtapchangerupperbandwidth
)
-
loadtapchangerminimumchange
(
type: esriFieldTypeDouble, alias: loadtapchangerminimumchange
)
-
starthour
(
type: esriFieldTypeSmallInteger, alias: starthour
)
-
stophour
(
type: esriFieldTypeSmallInteger, alias: stophour
)
-
powerfactor
(
type: esriFieldTypeDouble, alias: powerfactor
)
-
coolingtype
(
type: esriFieldTypeSmallInteger, alias: Cooling Type
)
-
ganged
(
type: esriFieldTypeSmallInteger, alias: Ganged
)
-
serialnum
(
type: esriFieldTypeString, alias: Serial Number, length: 50
)
-
currentlimiting
(
type: esriFieldTypeSmallInteger, alias: Current Limiting
)
-
demand
(
type: esriFieldTypeString, alias: Demand, length: 50
)
-
ptctidnum
(
type: esriFieldTypeSmallInteger, alias: PT/CT ID Number
)
-
customerclass
(
type: esriFieldTypeSmallInteger, alias: Transformer Customer Class
)
-
configprimary
(
type: esriFieldTypeString, alias: Primary Configuration, length: 50
)
-
configsecondary
(
type: esriFieldTypeString, alias: Secondary Configuration, length: 50
)
-
oilvolume
(
type: esriFieldTypeInteger, alias: Oil Volume
)
-
oilvolumeunits
(
type: esriFieldTypeSmallInteger, alias: Oil Volume Units
)
-
weight
(
type: esriFieldTypeInteger, alias: Weight
)
-
weightunits
(
type: esriFieldTypeSmallInteger, alias: Weight Units
)
-
pcblevelppm
(
type: esriFieldTypeString, alias: PCB Level (ppm), length: 50
)
-
type
(
type: esriFieldTypeSmallInteger, alias: Transformer Type
)
-
cabinetuser
(
type: esriFieldTypeString, alias: Cabinet User, length: 50
)
-
vfiovercurrenttimedelay
(
type: esriFieldTypeDouble, alias: VFI Over Current Time Delay
)
-
vfigroundfault
(
type: esriFieldTypeInteger, alias: VFI Ground Fault
)
-
vfigfitimedelay
(
type: esriFieldTypeDouble, alias: VFI GFI Time Delay
)
-
vfitripcurve
(
type: esriFieldTypeString, alias: VFI Trip Curve, length: 50
)
-
vfiphasetrip
(
type: esriFieldTypeString, alias: VFI Phase Trip, length: 50
)
-
transconfiguration
(
type: esriFieldTypeString, alias: Transformer Configuration, length: 50
, Coded Values:
[unknown: unknown]
, [radial: radial]
, [feedthru: feed thru (loop)]
)
-
percentiz
(
type: esriFieldTypeString, alias: Impedence (%IZ), length: 50
)
-
transprotection
(
type: esriFieldTypeString, alias: Transformer Protection, length: 50
, Coded Values:
[0: non-internally fused]
, [1: internally fused]
)
-
deadfront
(
type: esriFieldTypeSmallInteger, alias: Dead Front
)
-
notes
(
type: esriFieldTypeString, alias: Notes, length: 2000
)
-
SymbolRotation
(
type: esriFieldTypeSmallInteger, alias: SymbolRotation
, Range: [0, 359]
)
-
spatialsource
(
type: esriFieldTypeSmallInteger, alias: Spatial Source
)
-
spatialconfidence
(
type: esriFieldTypeSmallInteger, alias: Spatial Confidence
)
-
CreateDate
(
type: esriFieldTypeDate, alias: CreateDate, length: 8
)
-
CreateUser
(
type: esriFieldTypeString, alias: CreateUser, length: 50
)
-
LastModDate
(
type: esriFieldTypeDate, alias: LastModDate, length: 8
)
-
LastModUser
(
type: esriFieldTypeString, alias: LastModUser, length: 50
)
-
wmsstatus
(
type: esriFieldTypeString, alias: wmsstatus, length: 50
)
-
unitid
(
type: esriFieldTypeString, alias: unitid, length: 50
)
-
comptype
(
type: esriFieldTypeInteger, alias: comptype
)
-
compkey
(
type: esriFieldTypeInteger, alias: compkey
)
-
VALIDATIONSTATUS
(
type: esriFieldTypeSmallInteger, alias: VALIDATIONSTATUS
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: SHAPE
)
Types:
ID: 12
Name: Secondary Arrester
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [221: overhead arrester]
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: c]
, [2: b]
, ...2 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 16
Name: Secondary Lighting
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [301: flood light]
, [302: streetlight]
, ...7 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: c]
, [2: b]
, ...2 more...
-
designtype:
Coded Values:
[0: unknown]
, [1: cobra head]
, [5: decorative]
, ...3 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
optype:
Coded Values:
[0: unknown]
, [30: High Pressure Sodium (HPS)]
, [32: Metal Halide (MH)]
, ...2 more...
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 22
Name: Secondary Service
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [421: single phase commercial]
, [422: single phase residential]
, ...4 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: c]
, [2: b]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [208: 208 V]
, [240: 240 V]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [120: 120 V]
, [240: 240 V]
, ...3 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 26
Name: Primary Circuit Breaker
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [502: single phase circuit breaker]
, [503: 3 phase circuit breaker]
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 29
Name: Primary Fuse
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [564: overhead cutout fused disconnect]
, [568: cabinet fuse]
, ...3 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
designtype:
Coded Values:
[0: unknown]
, [1: C]
, [2: E]
, ...10 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
model:
Coded Values:
[Cooper X-Limiter SMD-20 15.5kv 65CL: Cooper X-Limiter SMD-20 15.5kv 65CL]
, [Elastimold EFX Full Range 15.5kv 12: Elastimold EFX Full Range 15.5kv 12]
, [Elastimold EFX Full Range 15.5kv 20: Elastimold EFX Full Range 15.5kv 20]
, ...38 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
ratedpower:
Coded Values:
[0: unknown]
, [1: 1 amp]
, [3: 3 amps]
, ...27 more...
-
loadtapchangepercent:
Inherited
-
ganged:
Coded Values:
[0: unknown]
, [1: True]
, [2: False]
-
type:
Coded Values:
[0: unknown]
, [1: elbow fuse]
, [2: SF6 fuse holder]
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 31
Name: Primary Line Monitor and Relay
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [601: fault indicator]
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 36
Name: Primary Service
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [701: Industrial Customer OH]
, [704: Industrial Customer UG]
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
ctratio:
Coded Values:
[0: unknown]
, [25: 25:50]
, [50: 50:5]
, ...3 more...
-
ptratio:
Coded Values:
[0: unknown]
, [25: 25:50]
, [50: 50:5]
, ...3 more...
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 37
Name: Primary Switch
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [732: overhead 3 phase disconnect]
, [728: overhead single phase disconnect]
, ...6 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
ratedpower:
Coded Values:
[0: unknown]
, [1: 1 amp]
, [3: 3 amps]
, ...27 more...
-
loadtapchangepercent:
Inherited
-
ganged:
Coded Values:
[0: unknown]
, [1: True]
, [2: False]
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 38
Name: Transformer
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [785: overhead single phase]
, [788: overhead 3 phase]
, ...8 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
secondaryvoltagelinetoline:
Coded Values:
[0: unknown]
, [208: 208 V]
, [240: 240 V]
, ...3 more...
-
secondaryvoltagelinetoground:
Coded Values:
[0: unknown]
, [120: 120 V]
, [240: 240 V]
, ...3 more...
-
ratedpower:
Coded Values:
[0: unknown]
, [3000: 3 kVA]
, [5000: 5 kVA]
, ...22 more...
-
loadtapchangepercent:
Inherited
-
customerclass:
Coded Values:
[0: unknown]
, [1: commercial]
, [2: residential]
, ...2 more...
-
oilvolumeunits:
Coded Values:
[0: gallons]
, [1: litres]
-
weightunits:
Coded Values:
[0: pounds]
, [1: kilograms]
-
pcblevelppm:
Coded Values:
[<1: <1]
, [<2: <2]
, [<5: <5]
, ...3 more...
-
transconfiguration:
Inherited
-
transprotection:
Coded Values:
[unknown: unknown]
, [internally fused: internally fused]
, [non-internally fused: non-internally fused]
-
deadfront:
Coded Values:
[0: unknown]
, [1: True]
, [2: False]
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 41
Name: Primary Recloser
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [730: overhead single phase recloser]
, [744: overhead 3 phase recloser]
, ...2 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
normaldevicestatus:
Coded Values:
[0: unknown]
, [1: open]
, [2: closed]
, ...1 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
nominalvoltagelg:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [14400: 14.4 kV]
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
ratedpower:
Coded Values:
[0: unknown]
, [1: 1 amp]
, [3: 3 amps]
, ...27 more...
-
loadtapchangepercent:
Inherited
-
ganged:
Coded Values:
[0: unknown]
, [1: True]
, [2: False]
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 0
Name: Unknown
Domains:
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 43
Name: Primary SwitchCubicle
Domains:
-
ASSETTYPE:
Coded Values:
[58: Underground]
, [59: Submersible]
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
numphasesconstructed:
Coded Values:
[0: unknown]
, [1: 1]
, [2: 2]
, ...1 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
optype:
Coded Values:
[1: Air]
, [8: SF6]
, [9: Solid Dielectric]
, ...1 more...
-
loadtapchangepercent:
Inherited
-
SymbolRotation:
Inherited
-
spatialsource:
Coded Values:
[0: unknown]
, [1: As-built/work order]
, [2: CAD]
, ...3 more...
-
spatialconfidence:
Coded Values:
[0: unknown]
, [1: High]
, [2: Medium]
, ...1 more...
ID: 25
Name: Primary Arrester
Domains:
-
ASSETTYPE:
Coded Values:
[0: unknown]
, [481: elbow arrester]
, [482: line arrester]
, ...3 more...
-
lifecyclestatus:
Coded Values:
[0: unknown]
, [1: proposed]
, [2: approved]
, ...8 more...
-
ownedby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
maintby:
Coded Values:
[1: City]
, [2: private]
, [100: other]
-
acquisition:
Coded Values:
[1: ECD (SP but considered CD for rate model)]
, [2: Not a City Asset]
, [3: SP (self-constructed or purchased)]
-
SUBNETWORKNAME:
Coded Values:
[12-B-1: 12-B-1 (12000-S6)]
, [13-B-1: 13-B-1 (13-9)]
, [14-B-12: 14-B-12]
, ...57 more...
-
phasesnormal:
Coded Values:
[0: de-energized]
, [1: C]
, [2: B]
, ...2 more...
-
nominalvoltage:
Coded Values:
[0: unknown]
, [2400: 2.4 kV]
, [4160: 4.16 kV]
, ...3 more...
-
phasefrequency:
Coded Values:
[60: 60 hz]
-
numphasesconstructed:
Coded Values:
[0: unknown]
, [1: 1]
, [2: 2]
, ...1 more...
-
manufacturer:
Coded Values:
[0: unknown]
, [1: ABB/Westinghouse]
, [2: BCT]
, ...27 more...
-
p2sphaseshift:
Inherited
-
p2tphaseshift:
Inherited
-
timedelay:
Inherited
-
tripcount:
Inherited
-
tapmaxchange:
Inherited
-
loadtapchangepercent:
Inherited
-
transprotection:
Inherited
-
SymbolRotation:
Inherited
Supported Operations:
Query
Query Attachments
Query Analytic
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata